Project Background
The pharmaceutical industry demands high precision, cleanliness, and stability from automated equipment. A pharmaceutical equipment manufacturer faced the following challenges in a robotic arm project for an automated production line:
- High-precision positioning: Repeatability within ±1 arcmin
- High rigidity: Maintain stability under frequent starts/stops and high loads
- Compact space constraints: Limited installation space, requiring miniaturization
- High-temperature resistance: Continuous operation at 80°C
- Cleanroom compatibility: Compliant with ISO Class 5 standards
Solution
We customized a dedicated RV cycloidal gear reducer with modular design and high-precision manufacturing to perfectly match the joint drive requirements of the robotic arm.
Installation Method
Flange direct connection with servo motor ensures seamless integration, compact structure, and easy maintenance.
Key Parameters and Performance
Parameter | Value/Description |
---|---|
Reduction Ratio | 100:1 |
Output Torque | 120 N·m |
Size Requirements | Diameter ≤ 90mm, Total Length ≤ 120mm |
Material | High-alloy steel + surface hardening treatment |
Operating Temperature | -20°C to +100°C |
Backlash | ≤ 1 arcmin |
Protection Class | IP65 |
Project Results
The customized RV reducer was successfully applied to the customer's pharmaceutical robotic arm system, achieving:
- Repeatability of ±0.8 arcmin, exceeding industry standards
- No performance degradation at 80°C continuous operation
- Compact design compatible with the customer's mini robotic arm structure
- High rigidity output shaft effectively suppresses vibration, improving system stability
Customer Feedback
“Your RV reducer performed excellently in terms of precision, stability, and durability, fully meeting the stringent requirements of our pharmaceutical automation equipment.”